Archive data import
This is a technical documentation for the import plugin of archive data from a hierarchically organised Excel file.
Last updated
This is a technical documentation for the import plugin of archive data from a hierarchically organised Excel file.
Last updated
Name | Wert |
---|---|
This documentation describes the installation, configuration and use of the import plugin for archive data from a hierarchically organised Excel file.
This plugin can be used to import data from an Excel file. The individual lines are converted to Goobi processes and images can be imported automatically. In addition, a hierarchical EAD tectonics is also created.
To be able to use the plugin, the following files must be installed:
In addition, the XML database BaseX
must be running in the background and set up correctly. The installation is described in detail here.
To use the import, the mass import area must be opened in the production templates and the plugin intranda_import_crown
selected in the file upload import tab. An Excel file can then be uploaded and imported.
The Excel file to be imported must contain the following structure as an example:
This Excel file is read and analysed line by line during the import. It first checks how deeply the current row has been indented. If there is no indentation, the root element of the tectonics is present. Otherwise, these are sub-elements. The parent element of each row is the last element with a lower indentation.
Next, the content of the cells is read. Both the hierarchically indented cells and any existing fixed columns are taken into account.
Which content is imported for which EAD or metadata field is defined in the corresponding configuration file.
If the first piece of information within the Excel file is formatted bold, a process is also created for this row and a search is carried out for associated images. These images are expected within a configured folder in subfolders named after the inventory number. These can either be organised flat in a folder list or follow the same hierarchical structure as the tectonics.
If a folder is found, all the files it contains are listed and checked according to the following rules:
ignore all data that is not a tif
, jpg
or wmv
.
ignore all files that contain the word compressed
.
if a file without the suffix _edited
is found, check if there is a file with the same name and the suffix _edited
. If so, ignore the current file and use the version with _edited
.
if an jpg
file was found, check if there is a tif
with the same name, if yes, ignore the jpg
file and use the tif
The configuration is done in the file plugin_intranda_import_crown.xml
:
The <template>
field defines the production template for which the current configuration is to be used. As the <config>
element is repeatable, different configurations are possible for different production templates. For example, there may be a different configuration for the imperial crown than for the imperial orb.
The <runAsGoobiScript>
field controls whether the import is executed directly in the user session or in the background as GoobiScript. The use of GoobiScript is recommended for larger Excel files.
<startRow>
determines which row is the first data row of the Excel file. This allows further information such as headers, descriptions or help texts to be specified above it, which are then ignored by the import.
The <basex>
area defines where the EAD tectonics are saved. The sub-element <database>
contains the name of the BaseX database, which must already exist. The name of the EAD file is defined in <filename>
. If this name is already used, existing data is overwritten.
The root folder of the images is defined in the <images>
element. <metadata>
contains the metadata to be used. The structure type is defined using <doctype>
and the fields <title>
, <identifier>
and <description>
contain the names of the metadata for title, inventory number and description text.
The mapping of the metadata takes place within the <metadata>
block. The publication type to be used for the individual METS files is defined here in <doctype>
.
The node type to be used can then be defined if it is available as an Excel column. This is done in <nodetype>
. If this is not the case, the field can be left empty. In this case, file
is used for all nodes for which a process has been created; all other nodes are assigned the type folder
.
The generation of task titles is configured in <title>
. The same rules apply here as in the normal creation mask. In addition, the two keywords first
and second
are available to access the content of the two hierarchical fields.
The metadata mapping to EAD and METS/MODS is then configured. The first hierarchical field is defined in <firstField>
, <secondField>
optionally contains the content of the second field. If only one field is used, it can be deactivated using enabled="false"
. Additional, permanently defined columns can be configured using <additionalField>
. Here, the heading of the column must be specified in the column
attribute. The other configuration options are identical to the other two. The metadataField
field defines the metadata to be used within the METS/MODS file. The corresponding field in the EAD node is defined in eadField
and level
specifies the area in which the metadata is located.
In addition, a field must be marked as identifier="true"
. The content of this field must be unique for each line within the document and is used for the id
of the EAD nodes and the metadata NodeId
. It is used to link EAD nodes and Goobi processes.
Identifier
intranda_import_crown
Repository
Licence
GPL 2.0 or newer
Last change
25.07.2024 12:03:18
Shelfmark
Comment
CR_1
Reichskrone
CR_1
comment
CR_1_A-H
Kronreif
CR_1_A-H
another comment
CR_1_A
Platte A, Stirnplatte
CR_1_A_GrPl
Grundplatte
CR_1_A_GrPl_1
Riss in Grundplatte (?)
CR_1_A_GrPl_2
Riss in Grundplatte und Grundplattenperldrahtumsäumung
CR_1_A_GrPl_3
Riss in Grundplatte
CR_1_A_GrPl_4
Riss in Grundplatte und Grundplattenperldrahtumsäumung
CR_1_A_GrPl_5
Deformierung von Grundplatte
CR_1_A_GrPl_6
Steg durch Öffnung in Grundplatte hinter Fa_4
CR_1_A_GrPl_7
4 Löcher in Grundplatte
CR_1_A_GrPl_8
Löcher in Grundplatte
CR_1_A_GrPl_9
4 Löcher in Grundplatte
CR_1_A_GrPl_10
angelöteter Span auf Grundplatte
CR_1_A_SchS
Scharnierstift
CR_1_A_SchR
Scharnierrohre
CR_1_A_SchR_1
Scharnierrohr
CR_1_A_SchR_2
Scharnierrohr
CR_1_A_SchR_3
Scharnierrohr
CR_1_A_GrUm
Grundplattenperldrahtumsäumung
CR_1_A_GrUm_1
Grundplattenperldrahtumsäumung
CR_1_A_GrUm_2
Grundplattenperldrahtumsäumung
CR_1_A_GrFi
Grundplattenfiliigrandekor
CR_1_A_RoeG
Röhrchen mit Granalien
CR_1_A_RoeG_1
Röhrchen mit Kugelpyramide
CR_1_A_RoeG_2
Röhrchen mit Kugelpyramide